Products

Electricide Chlorine Dioxide Systems

Ozone Bottled Water Disinfection Systems

Fiberstrut Channel and Fasteners

ProMinent Chemical Dosing Equipment

Fristam Stainless Steel Hygienic Pumps

Atlantium HOD UV Disinfection

Glasco UV

LSM Pumps Hose Pumps

Likuid Nanotek Ceramic Membranes

IPM Systems Powder Feed Systems

Chemical Dosing Systems

Ozone Systems

Chlorine Dosing Systems

Sodium Hypochlorite Dosing Systems

Gas Chlorine Dosing Systems

Chlorine Dioxide Dosing Systems

Electrochemical Generation Systems

Acid Chlorite Generation Systems

UV Disinfection Systems

Chemical Dosing Systems

Building Mount Dosing Systems

Skid Mount Dosing Systems

Fluoride Dosing Systems

Services

Chemical Dosing Systems ProMinent Ozone Chlorine Dioxide UV CircleClear Backwash Recovery Sodium Hypochlorite Aickinstrut Fiberstrut

us flag 

United States Office

aust flag 

Australia


United States

P: 702-938-6418  F: 702-938-4118  salesus@dioxide.com
Suite B-562 / 2654 W Horizon Ridge Pkwy
Henderson NV 89052-2803

Sydney (NSW)
P: +612 9999 4594  F: +612 9999 4534  sales@dioxide.com
Unit 9, 5-7 Prosperity Pde, Warriewood NSW 2102 Australia
Perth (WA)

P: +618 9337 5415  F: +612 9999 4534  saleswa@dioxide.com
Melbourne (Vic)

P: +613 9005 1681  F: +612 9999 4534  salesvic@dioxide.com

Home

Products

Chemical Dosing Systems

Applications

News

Services

Contact
Dioxide Pacific


Sodium Hypochlorite Dosing Systems
Dioxide Pacific provides sodium hypochlorite dosing systems in package formats which can include bulk chemical storage tanks, chemical bunding, tanker unloading areas, metering pumps, chlorine residual analysers, electrical control panels with site installation and commissioning. Some typical examples are highlighted below.
 

Disinfection of Potable Water at Mine Camp Site
Dioxide Pacific was engaged by a large mining company in north Western Australia to provide a shipping container mounted sodium hypochlorite dosing system. Water is stored in 2 x 1ML reservoirs which are used for potable water and fire service. Water is recirculated by a 250 m3/hr centrifugal pump between the two reservoirs. Sodium hypochlorite is provided in 1,000L IBC’s and placed into a fiberglass IBC bund. One Delta dosing pump with degassing solenoid injects sodium hypochlorite at a controlled rate based on the chlorine setpoint of 2ppm. A chlorine residual analyser (D1Cb) is provided with CTE sensor. The complete system is mechanically and electrically installed in a 20ft shipping container, painted to the customer specifications. Dioxide Pacific provided 2D and 3D GA drawings so the customer knew exactly what would be provided before arrival on site. Please click on the picture to the right to view the 3D presentation on YouTube.
 

sodium hypochlorite dosing system

scrubber chlorine dosing system

Replacement of Electrolytic Chlorination with Sodium Hypochlorite for Odour Control on Scrubber
Logan Pollution Control Centre originally had an electrolytic chlorination system operating to produce chlorine in recirculating scrubber liquor. This was done by adding salt to the liquor and by-passing some of the recirculation flow through the electrolytic cells. This system was fraught with many problems including fouling of the cells and subsequent manual cleaning of the cells with acid. OH&S risk assessment determined that sodium hypochlorite was a better alternative.

The old system was removed and replaced with a sodium hypochlorite dosing plant. Dual IBC chemical tanks (duty and standby) were installed in fibreglass IBC bunds. Chemical is delivered and placed by forklift into the IBC bund. Chemical dosing equipment is mounted on an HDPE backboard which is also mounted to the scrubber outside wall. Chemical dosing lines are run through the wall to the scrubber recirculation line. Chlorine residual is controlled via redox measurement and an auto-tune PID controller. pH control is also included with caustic dosing to maintain pH at around 8.0 and ORP at 750 mV. Conductivity of the scrubber liquor is monitored and controlled via an automatic bleed valve. The complete system was designed, supplied and installed by Dioxide Pacific. It has achieved its aim of reducing operator involvement with chemical handling and increased reliability and therefore odour complaints.
 

Potable Water Disinfection for Airport
Sodium hypochlorite is pumped from 20L drums into a 60L tank using a drum pump. At the same time, automatic dilution of the hypochlorite from 12.5% to 6% occurs (to extend the life of the hypochlorite). Water is recirculated from the filtered water storage tank through the dosing skid and back to the tank again.

Sodium hypochlorite is dosed with duty and standby dosing pumps using an auto-changeover timed sequence. Chlorine residual in the water is monitored using a residual analyser and controlled to a set point of 1 ppm.

The skid is made from HDPE and FiberStrut for chemical resistance and is assembled complete mechanically and electrically prior to delivery.

Click on the picture to the right to view a 3D presentation of this plant(Youtube Link)
 

sodium hypochllorite dosing system


For more information on sodium hypochlorite dosing systems or to obtain a quotation, please complete the feedback form on our Contact page.